← Back to products
Thermo Fisher Scientific · SpeedVac Vacuum Concentrators › Individual vacuum concentrators

Savant SpeedVac SPD120

Obtain the necessary components for molecular biology applications with Thermo Scientific™ Savant™ SpeedVac™ SPD120 vacuum concentrator and kits.

Overview

Overview

Obtain the necessary components for molecular biology applications with Thermo Scientific™ Savant™ SpeedVac™ SPD120 vacuum concentrator and kits.

These modular vacuum concentrators provide flexibility for your benchtop space. They are ideal for evaporation of non-aggressive organics. Choose from one of 2 kits available: SPD120P1 SpeedVac kit for standard evaporation or SPD120 P2 SpeedVac™ kit for lyophilization. All SpeedVac kits contain all the necessary components under one model number.

Space-saving design:

  • Automatic bleeder valve for un-attended start/stop
  • Digital display of parameters for easy, reproducible selection
  • Three user defined programs that can be modified and saved
  • Independent timers for both heat and run and audible alarm when run is completed
  • PTFE-coated chamber for superior chemical resistance and easy cleaning
  • Match up with an appropriate cold trap, vacuum pump or chemical trap for a complete concentration/drying system

Product Features:

  • Basic molecular biology applications with increased microplate capacity
  • Simple display and programming
  • Six programs available
  • Enhanced evaporation model, organic compatible
  • Radiant glass cover to accelerate evaporation and reduce drying time
  • Vacuum end point mode terminates run when preset vacuum level is reached
  • Digital display of vacuum, temperature and time section
  • Latched lid and lid lock indicator ensuring user safety during operation

SpeedVac SPD120 P1 Kit includes:

  • SpeedVac concentrator
  • Universal vacuum system (UVS450) including an oil-free vacuum pump and a -50 °C refrigerated vapor trap
  • Glass condensation flask (GCF400)
  • 40 x 1.5 mL rotor (RH40-11)
  • Tubing package including 12’ of thick-walled vacuum tubing, cutter, clamps and fittings, BV130 manual bleed valve and instructions
  • CryoCool heat transfer fluid (1 L)

SpeedVac SPD120 P2 Kit includes:

  • SpeedVac concentrator, basic molecular biology
  • -105 ºC, ultra-low temperature refrigerated vapor trap
  • VPL120 high vacuum pump
  • 40 x 1.5 mL rotor (RH40-11)
  • Universal tubing package (TFK100)
  • Digital vacuum gauge
  • Chemical trap kit for use with disposable cartridge
  • Disposable cartridge with color indicator for trapping acids and water vapor
  • Glass condensation flask
  • Vacuum pump lubricating oil
  • CryoCool™ heat transfer fluid (1 L)

Solvent and solvent combinations

  • Acetonitrile
  • Ethanol
  • Isopropanol
  • Methanol
  • Water
  • Acetonitrile and water
  • Ethanol and water
  • Methanol and water
  • Ammonium hydroxide

Typical applications:

  • Drying biomolecules in HPLC fractions
  • Evaporating purification solvents
  • Drying extracts of natural products in drug assays
  • Lyophillization

Individual Vacuum Concentrators

Quick, safe and efficient evaporation

SpeedVac systems use the state-of-the-art centrifugation, vacuum and heat technologies for removing solvents and concentrating samples while maintaining sample integrity. A wide and diverse product range is able to provide solutions for a wide variety of solvent applications ranging from the traditional drying down of DNA preparations in water and methanol, to the more complex and aggressive applications presented by the combinatorical chemistry and drug discovery sectors of the pharmaceutical industry.

We also offer simple prepackaged Speedvac Vacuum Concentrator Modular Kits for popular applications and a wide array of SpeedVac rotors.

Choose your individual SpeedVac Vacuum Concentrator

  • Protein, enzymes, HPLC fractions applications
  • Organic solvents, drug discovery applications

Choose from the individual SpeedVac Vacuum Concentrators below for protein, enzyme, and HPLC fraction applications

Choose from the individual SpeedVac Vacuum Concentrators below for organic solvents and drug discovery applications

Protein, enzymes, HPLC fractions applications

Organic solvents, drug discovery applications

Smart Note: Savant SpeedVac System

When the quality of your results hinges on the quality of synthesized oligos

As oligos are being aggressively leveraged in research and clinical applications such as detecting, characterizing, and developing therapeutics and vaccines, the quality of synthesized oligos is critical. The Savant SpeedVac system enhances speed and reliability so you can have complete confidence in the quality of your oligos as well as the applications they serve.

Features of SpeedVac Vacuum Concentrators

Focused on ease of use

  • User interface allows use of 4 preset programs and 8 user defined programs to set heat, run time, ramp rate and vacuum level for efficient operation.
  • The heavy-duty universal rotor is optimized for efficient large-sample processing while accommodating various sample handling formats, such as microcentrifuge tubes, microplates, and 250mL flasks

Samples stay safe for reliable evaporation

  • Standard glass lid locks securely to help ensure safety for samples and users. Hands free operation when loading or unloading the rotor with the lid stay mechanism. An audible alarm alerts the user when the operation is finished.

Reliable data collection

  • Ability to download live run data from a USB port enhances data integrity.

Specifications

Savant™ SpeedVac™ SPD120 Vacuum Concentrator and Kits (Cat. No. SPD120-230)

Certifications UL Listed to US and Canadian requirements. CE marked
Description SpeedVac SPD120 Vacuum Concentrator
Electrical Requirements 230 V 50 Hz
Includes Vacuum Concentrator
Model Medium capacity glass lid
Unit Size Each

Savant™ SpeedVac™ SPD120 Vacuum Concentrator and Kits (Cat. No. SPD120P1-230)

Certifications UL Listed to US and Canadian requirements. CE marked
Description SpeedVac SPD120 Vacuum Concentrator Kit
Electrical Requirements 230 V 50 Hz
Includes Kit for Standard Evaporation
Unit Size Each

Savant™ SpeedVac™ SPD120 Vacuum Concentrator and Kits (Cat. No. SPD120P2-230)

Certifications UL Listed to US and Canadian requirements. CE marked
Description SpeedVac SPD120 Vacuum Concentrator Kit
Electrical Requirements 230 V 50 Hz
Includes Kit for Standard Evaporation Including Lyophilization
Unit Size Each

Available models

SPD120SPD210SPD130DLX
Programmability 3 3 3
Preset programs by solvent type 3 3 3
User defined programs 3 0 0
Capacity 120 x 1.5mL tubes 2 deep well plates 6 shallow well plates (and other tube & vial formats) 200 x 1.5mL tubes 4 deep well plates 12 shallow well plates (and other tube & vial formats) 120 x 1.5mL tubes 2 deep well plates 6 shallow well plates (and other tube & vial formats)
Type of lid Glass Glass Radiant Glass
Vacuum ramp / vacuum gauge No No No
Solvent types Water, alcohol, methanol, acetonitrile, non-aggressive solvents Water, alcohol, methanol, acetonitrile, non-aggressive solvents Water, alcohol, methanol, acetonitrile, aggressive low boiling point solvents
Order now SPD120-115: 115V/60HzSPD120-230: 230V/50Hz SPD210-115: 115V/60HzSPD210-230: 230V/50Hz SPD130DLX-115: 115V/60HzSPD130DLX-230: 230V/50Hz

Available models

SPD140DDASPD300DDA
Programmability 12 12
Preset programs by solvent type 4 4
User defined programs 8 8
Capacity 120 x 1.5mL 2 deep well plates 6 shallow well plates (other tube & vial formats) 200 x 1.5mL 8 deep well plates 20 shallow well plates (other tube & vial formats)
Type of lid Heated Glass Heated Glass
Vacuum ramp / vacuum gauge Yes Yes
Solvent types Water, low & high boiling, more aggressive solvents (DMSO, TFA), HPLC Water, low & high boiling, more aggressive solvents (DMSO, TFA), acids, bases, HPLC
SPD140DDA-115: 115V/60HzSPD140DDA-230: 230V/50Hz With PRO rotor systemSPD300DDAA-115: 115V/60HzSPD300DDAA-230: 230V/50HzWithout rotorSPD300DDA-115: 115V/60HzSPD300DDA-230: 230V/50Hz

Documents

Product information, images, documents and videos: Thermo Fisher Scientific. View on manufacturer website Source 2 Source 3 Source 4